Goldstar Air Conditioner LWC061JGMK1 User Manual

ROOM AIR CONDITIONER  
SERVICE MANUAL  
CAUTION  
BEFORE SERVICING THE UNIT,  
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.  
D
r
y
F
a
n
C
o
o
l
MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011,  
LWJ0611PCG, LWC061JGMK1  
 
1.2 SPECIFICATIONS  
M6003R  
WM-6011  
LWJ0611PCG  
LWC061JGMK1  
MODELS  
ITEMS  
M5403R  
M5203R  
M5203L  
COOLING CAPACITY (BTU/h)  
POWER SUPPLY (Phase, V, Hz)  
INPUT (W)  
5,300  
5,200  
5,200  
1ø, 115V, 60HZ  
470  
6,000  
6,000  
530  
4.8  
610  
5.6  
620  
5.8  
OPERATING CURRENT (AMP.)  
REFRIGERANT CONTROL  
REFRIGERANT CHARGE (R-22)  
INSIDE FAN  
4.3  
CAPILLARY TUBE  
230g (8.1 Oz )  
330g(11.6 Oz) 335g (11.8 Oz) 235g (8.3 Oz)  
TURBO  
OUTSIDE FAN  
PROPELLER FAN WITH SLINGER RING  
2-WAY (RIGHT AND LEFT)  
TOP-DOWN  
AIR DISCHARGE  
CHASSIS  
• OVERLOAD PROTECTOR FOR COMPRESSOR  
• INTERNAL PROTECTOR FOR FAN MOTOR  
PROTECTOR  
TEMPERATURE CONTROL  
ROTARY SWITCH  
FAN MOTOR  
THERMISTOR  
5 POSITIONS (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL)  
6 POLES, 16W  
6 POLES, 21.3W 6 POLES, 24W  
6 POLES, 21.4W  
• NOTE: Specifications are subject to minor change without notice for further improvement.  
1.3 SAFETY PRECAUTIONS  
1.4 INSULATION RESISTANCE TEST  
1. When servicing, set the POWER of CONTROL  
BOARD to Off and unplug the power cord.  
2. Observe the original lead dress.  
If a short circuit is found, replace all parts which  
have been overheated or damaged by the short cir-  
cuit.  
3. After servicing, make an insulation resistance test  
to prevent the customer's exposure to shock  
hazards.  
1. Unplug the power cord and connect a jumper  
between 2 pins (black and white).  
2. The grounding conductor (green or green and yel-  
low) is to be open.  
3. Measure the resistance value with an ohm meter  
between the jumpered lead and each exposed  
metallic part on the equipment at all Mode [except  
POWER OFF].  
4. The value should be over 1 M.  
—3—